SYSTEM DELAYS & TIMEOUTS (ADDRESS 2400, 2401, 2403-2405, 4082 & 4083)
ADDRESS 2400
Reset
Output
LEFT
RIGHT
Output
Timeout
Timeout
(min.)
(min.)
[Default = blank (•) blank (•)]
[Default = blank (•) blank (•) ]
!
DATA ENTRIES
DELAY/
LEFT
RIGHT
TIMEOUT
!
blank (•) blank (•)
0 min.
!
blank (•)
1
1 min.
blank (•)
2
2 min.
blank (•)
3
3 min.
blank (•)
4
4 min.
blank (•)
5
5 min.
blank (•)
6
6 min.
1
blank (•)
16 min.
OUTPUT TIMEOUTS: If a timeout of "0 min." is selected, then the output will remain active (ON)
until the system is reset or disarmed. For UL Residential Installations, the minimum timeout is 4
F
F
255 min.
minutes. For UL Commercial Installations, the minimum timeout is 15 minutes.
KEYPAD SYSTEM CODES (ADDR ESS 0490, 0495 & 0500)
PANEL ACCESS CODE: Enter up to 6 digits to activate a door strike while the area is disarmed.
!
1. Enter in both left and right digits of address locations.
!
2. Valid entries are: 0-9.
Note: Also, "Access Control on Aux. Output" (Address 2418) and "Aux. Output Access Control Timeout" (Address 2402) must both be
enabled.
AMBUSH CODE: Enter a 2-digit code used just prior to disarming and will activate an Ambush Condition, causing a SILENT report to
be sent to the central station.
!
1. Enter in both left and right digits of address locations.
!
2. Valid entries are: 0-9.
Note: Also, "Enable Keypad Ambush" (Address 2440-2446), "Report on Ambush Alarm" (Address 1125, 1127, 1135 & 1137) and
"Ambush Code" (Address 0900) must all be enabled.
DEALER SECURITY CODE: Enter up to 6 digits to be used by the dealer to enter programming.
!
1. Enter in both left and right digits of address locations.
!
2. Valid entries are: 0-9.
Note: If left blank, the Master Security Code must then be used to enter programming.
X
GEM-X255 Programming Instructions
ADDRESS 2401
Burg.
Aux.
Alarm
LEFT
RIGHT
Output
Timeout
(min.)
1. Select delay/timeout (0-255 min.) from the table shown.
2. Enter in corresponding address locations above (left and right digits).
3. For a desired delay/timeout not listed do the following:
A. Choose a desired delay/timeout, ex: 20 min.
B. Divide it by 16
Panel Access
Code
[Default = blank (•) blank (•) from address 0490-0492]
Ambush
Code
[Default = blank (•) blank (•)]
Dealer Security
Code
[Default = blank (•) blank (•) from address 0500-0502]
ADDRESS 2403
Pulse
LEFT
RIGHT
Alarm
Output
Timeout
(min.)
[Default = 1 blank (•)]
[Default = blank (•) 1]
1 Quotient
Left Digit
16 20
16
4 Remainder
Right Digit
ADDRESS 0490-0492
0490
0491
0492
L
R
L
R
L
R
ADDRESS 0495
LEFT
RIGHT
ADDRESS 0500-0502
0500
0501
0502
L
R
L
R
L
R
WI1092B 9/02
ADDRESS 2405
ADDRESS 2404
Fire
Output
LEFT
LEFT
RIGHT
Timeout
(min.)
[Default = blank (•) blank (•) ]
ADDRESS 4082
Report
Cancel
LEFT
Window
(sec.)
[Default = blank (•) blank (•)]
ADDRESS 4083
Auto
Disarm
LEFT
Rearm
Delay
(min.)
[Default = blank (•) blank (•)]