Start Pump; Adjusting The Water Temperature In The Boiler; Adjusting The Maximum Flame Level - RED practika 28-33 Use And Installation Manual

Table of Contents

Advertisement

red

Start Pump

9.2.13.
This function manually starts the circulation pump to run the circulation test on the system.
9.3.

Adjusting the water temperature in the boiler

The water temperature is displayed in real time on the start screenshot of the control panel. The boiler set
point (TH
O) is the desired temperature of the water in the boiler. When this temperature is reached, the
2
boiler diminishes its performance to avoid overheating. The default temperature set is 65°C but it can be set
between 50°C and 80°C. If the user wishes to change this value, (s)he can do so as follows:
press key D to enter the settings screenshot.
Press key F for 1 second until the parameter setting is shown.
Press F and C to change the value, and confirm with D.
65°C H2O
Esc
-
Water temp.
9.4.

Adjusting the maximum flame level

The maximum flame level is the maximum level the boiler can reach during modulation. If for instance the
setting is Fire: 3, when the boiler modulates up, it will never exceeds the flame level 3. If the user wishes to
change this value, (s)he can do so as follows:
press key D to enter the settings screenshot.
Press key E for 1 second until the parameter setting is shown.
Press F and C to change the value, and confirm with D.
65°C H2O
Esc
-
Menu structure
USE AND INSTALLATION MANUAL
21.04
OFF
65°C
Set
+
21.04
OFF
Ok
Fire
+
PRACTIKA 28-33
Fire:5
TH2O:75°C
Esc
-
Fire:5
TH2O:75°C
Esc
-
Technical dept. - All rights reserved - Reproduction prohibited
70°C
Ok
Water temp.
+
Ok
Fire
+
Chapter 9
page 50

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents