Hayward TriStar SP322063EEV Owner's Manual page 3

Variable speed pump control
Table of Contents

Advertisement

TriStar Variable Speed Pump Control   ____                      ____________________________Page 3 of 16 
WARNING 
– 
from lawn mowers, hedge trimmers and other equipment. 
WARNING 
– 
death.  To reduce the risk of electric shock, see installation instructions and consult a professional electrician on how to bond pump. 
Also, contact a licensed electrician for information on local electrical codes for bonding requirements. 
Notes to the electrician:  Use a solid copper conductor, size 8 or larger.  Run a continuous wire from external bonding lug to 
reinforcing rod or mesh.  Connect a No. 8 AWG (8.4 mm 
motor housing and to all metal parts of swimming pool, spa, or hot tub, and to all electrical equipment, metal piping (except gas 
piping), and conduit within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub.  IMPORTANT ­ Reference NEC codes for 
all wiring standards including, but not limited to, grounding, bonding and other general wiring procedures. 
CAUTION:  The equipment and controls shall be located not less than 1 M horizontally from the spa or hot tub.  ATTENTION: 
Maintenir une distance minimale, mesuree dans un plan horizontal, de 1 M entre la cuve de relaxation et les appareils et commandes. 
CAUTION:  When required by the Canadian electrical code, part I, section 68, connect only to a circuit protected by a class A ground 
fault circuit interrupter.  ATTENTION:  Si l'installation est visee par la section 68 du code Canadien de l ielectricite, premiere partie, 
brancher uniquement a une derivation protegee par un disjoncteur differentiel de classe A. 
Body Suction Entrapment­ A differential pressure applied to a large portion of the body or limbs can result in an 
entrapment. 
Evisceration/ Disembowelment­ A negative pressure applied directly to the intestines through an unprotected suction outlet 
sump or suction outlet cover which is damaged, broken, cracked, missing, or unsecured can result in 
evisceration/disembowelment. 
Mechanical Entrapment­ There is potential for jewelry, swimsuits, hair decorations, fingers, toes, or knuckles to be caught 
in an opening of a suction outlet cover resulting in mechanical entrapment. 
­ Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. 
­ The maximum system flow rate shall not exceed the values shown in the "Pipe Sizing Chart" found at the bottom of page 5 
of the TriStar Owner's Guide (IS3200). 
­ Never use pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached. 
­ Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately. 
­ In addition to two or more suction outlets per pump installed in accordance with latest IAF (formerly NSPI) standards and 
CPSC guidelines, follow all national, state, and local codes applicable. 
­ Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended.
WWW.HAYWARDPOOL.COM              USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 
WARNING 
applicable local codes, regulations, and the National Electric Code (NEC).  Hazardous voltage can shock, 
burn, and cause death or serious property damage.  To reduce the risk of electric shock, do NOT use an 
extension cord to connect unit to electric supply.  Provide a properly located electrical receptacle.    Before 
working on pump or motor, turn off power supply to the pump. 
To reduce the risk of electric shock replace damaged wiring immediately.  Locate conduit to prevent abuse 
Failure to bond pump to pool structure will increase risk for electrocution and could result in injury or 
WARNING 
– 
Suction in suction outlets and/or suction outlet covers which are damaged, broken, cracked, missing, or 
unsecured cause severe injury and/or death due to the following entrapment hazards: 
Hair Entrapment­ Hair can become entangled in suction outlet cover. 
Limb Entrapment­ A limb inserted into an opening of a suction outlet sump or suction outlet cover that 
is damaged, broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling 
of the limb. 
WARNING 
­ When outlets are small enough to be blocked by a person, a minimum of two functioning suction 
outlets per pump must be installed.  Suction outlets in the same plane (i.e. floor or wall), must be 
installed a minimum of three feet (3') [0.91 meter] apart, as measured from near point to near 
point. 
­ Dual suction fittings shall be placed in such locations and distances to avoid "dual blockage" by 
a user. 
Risk of Electric Shock.  All electrical wiring MUST be in conformance with 
) solid copper bonding wire to the pressure wire connector provided on the 
Suction Entrapment Hazard. 
­ 
To Reduce the risk of Entrapment Hazards: 

Hide quick links:

Advertisement

Table of Contents
loading