TriStar Variable Speed Pump Control   ____                      ____________________________Page 12 of 16 
POOL & SPA CONTROLLER – BASIC OPERATION 
Event 
Performed function 
Power Off 
RTC 
Power On 
Check configuration 
and proceed to Stop 
Mode. 
Configuration OK 
Stop Mode 
Pump is stopped until 
RTC 
On time, or the user 
selects a preset on the 
keypad. 
Prime Mode 
Pump will prime first 
when a preset is 
selected during Stop 
Mode. 
End of prime 
Operate according to 
active mode with flow 
set for this mode and 
for preset time. 
Timer activates the 
System enters Prime 
system. 
Mode if the pump was 
stopped prior to On­ 
The system enters 
Period, or system enters 
On­Period 
first sequence step if 
pump was running prior 
to On­Period. 
System operates 
System advances 
during On­Period 
through sequence steps 
unil RTC 
Timer­Off time.  If 
sequence steps end 
before Timer­Off time 
is reached, system will 
default to P2 "Low 
Filter" speed. 
WWW.HAYWARDPOOL.COM              USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 
Keypad active functions 
All inactive 
operation only. 
System enters Stop Mode until 
RTC 
the user selects a preset on the 
keypad.  All other functions are 
disabled. 
Buttons 1­6 are active.  When 
the user selects a preset on the 
reaches Timer 
keypad, the system enters Prime 
Mode.  After priming, the 
system operates according to the 
preset that was selected. 
Pressing Time Up/Dn causes 
remaining time for Prime Mode 
to be displayed. 
Pressing 1­6 changes the preset 
which will be activated upon 
completion of Prime Mode. 
Pressing Flow Up/Dn displays 
pump speed.  Pump speed 
cannot be changed during Prime 
Mode. 
After Prime Mode is completed, 
the pump will operate according 
to the preset that was selected, 
and will re­enter Stop Mode 
when the preset expires. 
% Flow and Time buttons as 
well as 1­6 buttons are active. 
The % Flow and Time buttons 
reaches 
may be used to temporarily 
change the flow and time of the 
current sequence step.  The 1­6 
buttons may be used to 
temporarily override the current 
sequence step.  The system will 
operate according to the selected 
preset and will advance to the 
next sequence step when the 
preset expires. 
reaches Timer On time, or 
Display message 
>OFF< 
HAYWARD POOL&SPA 
*VERSION 1.27* 
*PUMP STOPPED* 
*PRIME ­> *P3 
*PRIME ­> *P1 
8 min REMAINS 
*PRIME ­> *P4 
PUMP SPEED 85% 
P4. MEDIUM­HIGH 
(P4 indicates preset #4) 
*TIMER IS=ON* 
*PRIME MODE* 
S1    8:40am  *P3 
(S1 indicates sequence step #1; 
8:40am is current time; *P3 is 
currently running preset defined 
in sequence step S1) 
S1    8:40am  *P4 
(where *P4 is manually selected 
preset which overrides the 
current sequence step)