TriStar Variable Speed Pump Control ____ ____________________________Page 12 of 16
POOL & SPA CONTROLLER – BASIC OPERATION
Event
Performed function
Power Off
RTC
Power On
Check configuration
and proceed to Stop
Mode.
Configuration OK
Stop Mode
Pump is stopped until
RTC
On time, or the user
selects a preset on the
keypad.
Prime Mode
Pump will prime first
when a preset is
selected during Stop
Mode.
End of prime
Operate according to
active mode with flow
set for this mode and
for preset time.
Timer activates the
System enters Prime
system.
Mode if the pump was
stopped prior to On
The system enters
Period, or system enters
OnPeriod
first sequence step if
pump was running prior
to OnPeriod.
System operates
System advances
during OnPeriod
through sequence steps
unil RTC
TimerOff time. If
sequence steps end
before TimerOff time
is reached, system will
default to P2 "Low
Filter" speed.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Keypad active functions
4
All inactive
operation only.
System enters Stop Mode until
4
RTC
the user selects a preset on the
keypad. All other functions are
disabled.
Buttons 16 are active. When
4
the user selects a preset on the
reaches Timer
keypad, the system enters Prime
Mode. After priming, the
system operates according to the
preset that was selected.
Pressing Time Up/Dn causes
remaining time for Prime Mode
to be displayed.
Pressing 16 changes the preset
which will be activated upon
completion of Prime Mode.
Pressing Flow Up/Dn displays
pump speed. Pump speed
cannot be changed during Prime
Mode.
After Prime Mode is completed,
the pump will operate according
to the preset that was selected,
and will reenter Stop Mode
when the preset expires.
% Flow and Time buttons as
well as 16 buttons are active.
4
The % Flow and Time buttons
reaches
may be used to temporarily
change the flow and time of the
current sequence step. The 16
buttons may be used to
temporarily override the current
sequence step. The system will
operate according to the selected
preset and will advance to the
next sequence step when the
preset expires.
3
:
reaches Timer On time, or
Display message
>OFF<
HAYWARD POOL&SPA
*VERSION 1.27*
*PUMP STOPPED*
*PRIME > *P3
*PRIME > *P1
8 min REMAINS
*PRIME > *P4
PUMP SPEED 85%
P4. MEDIUMHIGH
(P4 indicates preset #4)
*TIMER IS=ON*
*PRIME MODE*
S1 8:40am *P3
(S1 indicates sequence step #1;
8:40am is current time; *P3 is
currently running preset defined
in sequence step S1)
S1 8:40am *P4
(where *P4 is manually selected
preset which overrides the
current sequence step)