TriStar Variable Speed Pump Control ____ ____________________________Page 13 of 16
Timer deactivates the
Pump is stopped and
system.
system enters Stop
Mode.
The system enters
OffPeriod
VARIABLE SPEED INTERFACE BASIC OPERATION NOTES:
3
) Timer Enabled (recommended): When the timer is enabled, the pump will be stopped when the control first receives power,
until the TimerON time is reached, at which time it will prime and proceed through the steps defined in the Sequencer menu. The
pump will stop when the system reaches the TimerOFF time. The pump may be manually stopped by pressing the 5 and 6 buttons
simultaneously for more than 5 seconds. Pressing any preset button after manually stopping the pump will cause the pump to prime
and operate according to the preset chosen.
Timer Disabled: When the timer is disabled, the pump will prime when the control first receives power, and will then default to P2
(Low Filter). It will continue to run according to P2 until power is disconnected from the control. After the pump has primed, the %
Flow and Time Up/Dn buttons, as well as the 16 buttons, are active. Pressing any of the 16 buttons will cause the pump to run
temporarily according to the set flow and time for the chosen preset. The % Flow and Time Up/Dn buttons may be used to
temporarily modify the set flow and time for the chosen preset. After the chosen preset expires, the pump will default back to P2. The
pump may be manually stopped by pressing the 5 and 6 buttons simultaneously for more than 5 seconds. After the pump is stopped, it
may be restarted by pressing the 5 and 6 buttons simultaneously again for more than 5 seconds, at which point the pump will prime
and then default to P2 (Low Filter).
4
) RTC – Real Time Clock
5
) Factory defaults are as follows. User/installer may note custom presets in the spaces provided.
Mode Name
PRIME
P1
P2
P3
P4
P5
P6
6
) If the sequencer is used, user/installer may note custom sequencer settings in the spaces provided.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
System enters Stop Mode as
before.
5 FEET OR LESS
MORE THAN 5 FEET
Low
Low Filter
Medium Low
Medium High
High Filter Cleaner
Maximum Flow
Sequence
Preset
Step
Used
Timer On
N/A
S1
S2
S3
S4
S5
S6
S7
S8
Timer Off
N/A
*TIMER IS=OFF*
*PUMP STOPPED*
Factory Presets
% Flow
Time
% Flow
65
6 min
85
8 min
50
30 min
50
30 min
50
30 min
50
30 min
50
30 min
50
30 min
Duration
Time Start
N/A
N/A
Custom Presets
Time