TriStar Variable Speed Pump Control   ____                      ____________________________Page 13 of 16 
Timer deactivates the 
Pump is stopped and 
system. 
system enters Stop 
Mode. 
The system enters 
Off­Period 
VARIABLE SPEED INTERFACE ­ BASIC OPERATION NOTES: 
)  Timer Enabled (recommended):  When the timer is enabled, the pump will be stopped when the control first receives power, 
until the Timer­ON time is reached, at which time it will prime and proceed through the steps defined in the Sequencer menu.  The 
pump will stop when the system reaches the Timer­OFF time.  The pump may be manually stopped by pressing the 5 and 6 buttons 
simultaneously for more than 5 seconds.  Pressing any preset button after manually stopping the pump will cause the pump to prime 
and operate according to the preset chosen. 
Timer Disabled:  When the timer is disabled, the pump will prime when the control first receives power, and will then default to P2 
(Low Filter).  It will continue to run according to P2 until power is disconnected from the control.  After the pump has primed, the % 
Flow and Time Up/Dn buttons, as well as the 1­6 buttons, are active.  Pressing any of the 1­6 buttons will cause the pump to run 
temporarily according to the set flow and time for the chosen preset.  The % Flow and Time Up/Dn buttons may be used to 
temporarily modify the set flow and time for the chosen preset.  After the chosen preset expires, the pump will default back to P2.  The 
pump may be manually stopped by pressing the 5 and 6 buttons simultaneously for more than 5 seconds.  After the pump is stopped, it 
may be restarted by pressing the 5 and 6 buttons simultaneously again for more than 5 seconds, at which point the pump will prime 
and then default to P2 (Low Filter). 
)  RTC – Real Time Clock 
)  Factory defaults are as follows.  User/installer may note custom presets in the spaces provided. 
Mode  Name 
PRIME 
P1 
P2 
P3 
P4 
P5 
P6 
)  If the sequencer is used, user/installer may note custom sequencer settings in the spaces provided. 
WWW.HAYWARDPOOL.COM              USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 
System enters Stop Mode as 
before. 
5 FEET OR LESS 
MORE THAN 5 FEET 
Low 
Low Filter 
Medium Low 
Medium High 
High Filter Cleaner 
Maximum Flow 
Sequence 
Preset 
Step 
Used 
Timer On 
N/A 
S1
S2
S3
S4
S5
S6
S7
S8 
Timer Off 
N/A 
*TIMER IS=OFF* 
*PUMP STOPPED* 
Factory Presets 
% Flow 
Time 
% Flow 
65
6 min 
85 
8 min 
50 
30 min 
50 
30 min 
50 
30 min 
50 
30 min 
50 
30 min 
50 
30 min
Duration 
Time Start 
N/A 
N/A 
Custom Presets 
Time 