Servicing Notes
• Servicing should be carried out annually by a competent person such as a CORGI
registered engineer. This is a condition of the Flavel guarantee schemes.
• The service should include visually checking the chimney and fire opening for
accumulations of debris and a smoke test to check for a positive up-draught in the
chimney.
• The burner assembly is designed to be removed as a complete unit for ease of access.
After any servicing work a gas tightness check must always be carried out.
• We recommend that during the annual service, replacement of the pilot is carried out.
The pilot must be changed as a condition of the extended guarantee.
4.1
REMOVING THE BURNER ASSEMBLY FROM THE FIRE.
a) Remove Ashpan, Fret assembly & Contemporary Trim from the front of the fire.
b) Isolate the gas supply and remove the inlet pipe from the appliance inlet elbow
c) Remove the glass frame, then remove the 2 off fixing screws which hold the pilot shield
in place.
d) Unscrew and remove the four screws which retain the burner. Carefully pull forwards
the burner/control assembly and remove from fire box
e) Refit in the reverse order and carry out a gas tightness test.
4.2
REMOVING THE PIEZO IGNITER
a) Remove burner as described in section 4.1 Disconnect the ignition lead from the piezo
and unscrew the retaining nut on the rear of the control panel. Withdraw the piezo from
the front of the control panel. Reassemble in reverse order and carry out a gas
tightness test.
4.3
REMOVING THE CONTROL VALVE FROM THE FIRE.
a) Remove the burner assembly as in section 4.1.
b) Pull the control knob off the control tap spindle.
c) Loosen and remove the three gas pipe retaining nuts from the control tap and release
the ends of the gas pipes from the control tap body. Loosen and remove the
thermocouple securing nut from the end of the control tap.
d) Unscrew the control tap locknut from the front of the control panel and remove the
control tap.
e) To refit a control tap, reassemble in reverse order noting that the control tap locates
with a flat in the control panel. Carry out a gas tightness test after reassembly.
Supplied By www.heating spares.co Tel. 0161 620 6677
SECTION 4

MAINTENANCE

14