Flavel Atlanta FAVRU0MN Installation And Maintenance Instructions Manual page 10

Table of Contents

Advertisement

g) Fit the wallplugs provided and screw the fixing eyes securely into the rear of the fire opening.
If the clearance at the rear of the fire is at the minimum specified for a precast flue application,
it may be necessary to bend over the fixing eyes after screwing them fully into the rear of a
pre-cast starter block.
i)
Uncoil the two fire fixing cables and thread one end of each of the cables through one of the
two holes on each side of the flue outlet shroud.
j) Position the fire carefully on the (protected) surface of the hearth and reach into the fire
opening. Thread each of the cables vertically downwards through the pair of fixing eyes on the
same side of the fire. Thread the free end of the cables through the corresponding circular
hole on each side of the lower rear of the fire. Carefully slide the firebox back into the fire
opening and pull both cables tight.
k) Thread a tensioning screw over each of the cables and ensure that the tensioning nut is
screwed fully up against the hexagon shoulder of the tensioning screw (this provides maximum
travel for the tensioning nut).
l) Fit a screwed nipple on to each of the cables and pull hand tight up against the tensioning
screw, then secure each nipple with a flat bladed screwdriver. See below
Supplied By www.heating spares.co Tel. 0161 620 6677