NOTE
19
- The Fusing Unit is hot. Be careful not to touch the
area carrying the WARNING! HIGH
TEMPERATURE label.
- Before changing the Oiling Roller, wait until the
surface temperature of the Fusing Unit falls and
make sure that the temperature is safe for
replacement.
WARNING! HIGH TEMPER-
ATURE label
- Loosen the installation screws (2 places) in the Oiling
20
Roller.
- Hold the grip and take out the Oiling Roller.
2
21
- Remove a new Oiling Roller from its carton.
22
- Insert the front end of the guide on the new Oiling
Roller into the installation hole of the Fusing Unit to
install the Oiling Roller.
Guides
NOTE
23
- Do not touch the Oiling Roller as its surface is
impregnated with silicone oil.
- Tighten the installation screws (2 places) in the Oiling
24
Roller.
- Hold the Lock Release Lever and push the Fusing
25
Unit in.
- The Fusing Unit will click into place when it is
installed correctly.