3.2

How to Set the Purpose

1. Press the MENU key. The main menu will appear on the screen.
2. Press the  or  button to select [Factory]. The factory menu title bar will appear
in gray color right side of the screen.
3. Hold down the CANCEL/HL OFF key and press the MENU key five times to acti-
vate the [Factory] menu.
ARPA
AIS
GPS
System
Initial
Tests
Sector Blanks
Units
Installation
Factory
Use this menu when setting up in factory
4. Press the ENTER key. The [Factory] menu becomes active and the cursor moves
to the right-hand column.
5. Press  or  to select [Purpose].
6. Press the ENTER key to show the setting window.
7. Press  or  to select the purpose required.
8. Press the ENTER key to set the purpose.
9. Press  to select [Model].
10. Press the ENTER key to show the setting window. The default setting is [8065
RTR-085A].
Note: For FR-8045, the default is [8045 RTR-088A]. No adjustment is necessary,
go to step 13.
11. Press  or  to select the appropriate model.
12. Press the ENTER key to set the model.
13. Press the CANCEL/HL OFF key to return to the main menu.
Menu
Language
Purpose
Purpose
Model
[Enter]: Enter [CANCEL/HL OFF]: Back
[Menu]: Exit
River
Sea
IEC
Russian River
Factory
: English
: Sea
: 8065 RTR-085A
26