4 Technical data

Right of technical changes reserved.
Rated voltage
Rated power input
Rated current input
Mains frequency
Rated voltage
Rated power input
Rated current input
Mains frequency
Power tool
Weight in accordance with EPTA procedure 01/2003
Single impact energy in accordance with EPTA proced-
ure 05/2009
Chuck
Hammering frequency under load
Protection class
NOTE
The vibration emission level given in this information sheet has been measured in accordance with a standardized test
given in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment
of exposure. The declared vibration emission level represents the main applications of the tool. However if the tool is
used for different applications, with different accessories or poorly maintained, the vibration emission may differ. This
may significantly increase the exposure level over the total working period. An estimation of the level of exposure to
vibration should also take into account the times when the tool is switched off or when it is running but not actually
doing the job. This may significantly reduce the exposure level over the total working period. Identify additional safety
measures to protect the operator from the effects of vibration such as: maintaining the tool and the accessories,
keeping hands warm, organization of work patterns.
Noise and vibration information (measured in accordance with EN 60745‑2‑6):
Typical A-weighted sound power level
Typical A-weighted emission sound pressure level
Uncertainty for the given sound level
Triaxial vibration value (vibration vector sum) for chisel-
ing, a
h, Cheq
Uncertainty (K)
18
TE‑S chuck /
tool designa-
Width (mm)
tion
TE‑S‑RD ³⁄₄"
100 V
15 A
50...60 Hz
220 V
1,750 W
8 A
50...60 Hz
Length (mm)
110 V
110 V
1,750 W
1,640 W
16 A
15 A
50 Hz
60 Hz
230 V
240 V
1,750 W
1,750 W
7.6 A
7.3 A
50 Hz
50 Hz
TE 1000‑AVR
12.5 kg
26 J
TE‑S
32.5 Hz
Protection class II (double insulated)
96 dB (A)
85 dB (A)
3 dB (A)
5 m/s²
1.5 m/s²
Width in
Length in
inches
inches
Inside ∅ ³⁄₄
127 V
1,750 W
14.5 A
60 Hz
220...240 V
1,750 W
8.0...7.3 A
50...60 Hz