Auto Report Door/Window State Time (Parameter Number 11, Parameter Size 1) interval time for auto
report the door/window state
Value
1 — 127 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours) (Default 12)
Auto Report Illumination Time (Parameter Number 12, Parameter Size 1) interval time for auto report the
temperature
Value
1 — 127 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours) (Default 12)
Auto Report Temperature Time (Parameter Number 13, Parameter Size 1) interval time for auto report the
temperature
Value
1 — 127 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours) (Default 12)

Command Classes

Supported Command Classes
Battery (version 1)
Association (version 2)
Configuration (version 1)
Manufacturer Specific (version 2)
Version (version 1)
Binary Sensor (version 2)
Multilevel Sensor (version 5)
Wake Up (version 2)
Basic (version 1)

Technical Data

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 7