2-4 Diagram of the Input/output circuit block
2-4
Diagram of the Input/output circuit block
。
DC24V
Imput
*In normal operation, 24 VDC is output as-is for charging the battery and from the input power supply.
If the 24 VDC from the input power supply becomes lower, the operation automatically switches to backup
operation, and 24 VDC is output from the battery.
S8BA-24D24D□□□LF
FET
Normal operation:ON
Backup operation:OFF
FET
Normal operation:ON
Backup operation:OFF
Charge/
Discharge
Battery
DC/DC Converter
Normal operation:ON
Backup operation:OFF
FET
Normal operation
Backup operation
2 Preparation
。
DC24V
Imput
2
29