Technical Data - Kemppi MasterTig MLS 2500 Operation Instructions Manual

Hide thumbs Also See for MasterTig MLS 2500:
Table of Contents

Advertisement

5. TECHNICAL DATA

MASTER MLS™ AND MASTERTIG MLS™ WELDING SYSTEM
Power source
Mains voltage
Rated power
40% ED MMA
60% ED MMA
100% ED MMA
30% ED TIG
60% ED TIG
100% ED TIG
Connection cable/fuse
Welding current range
(nominal values)
Max welding voltage
Electrode sizes to be welded
Welding current control
Open circuit voltage
Efficiency
Power factor
Open circuit power
External dimensions
length
width
height
weight, TIG
Power source
Mains voltage
Rated power
40% ED MMA
60% ED MMA
100% ED MMA
30% ED TIG
60% ED TIG
100% ED TIG
©
COPYRIGHT KEMPPI OY
Master(tig)3500 MLS, Master(tig) 3503 MLS
3~400V –15%...+10% (Mastertig 3500 MLS)
3~400V –15%...+20% (Master 3500 MLS)
3~230V –15%...+10% (Mastertig 3503 MLS)
3~230V –15%...+15% (Master 3503 MLS)
350A
285A
220A
400A
285A
220A
4 x 2.5S mm² - 5 m/16 A delayed (Master(tig) 3500 MLS)
4 x 6S mm² - 5 m/32 A delayed (Master(tig) 3503 MLS)
MMA
10 A/20.5V...350A/34.0V
TIG
5A/10.0V...400A/26.0V
45.0V/350A
Ø1.5...6.0 mm
stepless
80V
86% (350A/34,0V)
0.95 (350A/34,0 V)
approx. 10 W
500mm
180mm
390mm (650mm: TIG power source + cooling unit)
23 kg
MMA
21 kg
Master(tig) 2500 MLS, Master(tig) 2503 MLS
3~400V –15%...+10% (Mastertig 2500 MLS)
3~400V –15%...+20% (Master 2500 MLS)
3~230V –15%...+10% (Mastertig 2503 MLS)
3~230V –15%...+15% (Master 2503 MLS)
250A
205A
160A
300A
205A
160A
Master(tig) 2500, 2503, 3500, 3503 MLS™/ 0311 – 21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents