mounting the sliding Crosscut table to your saw:
19.
Remove the T-bolt (229) from the Crosscut Fence Lock Knob and insert the threaded shaft of the T-bolt up
through the slot on the crosscut fence as shown in Fig. 16. Pivot the fence counterclockwise and slide the
T-bolt into the T-slot in the right side of the sliding table top. Place the plastic washer (228) on the T-bolt
threaded shaft and then screw on the crosscut fence lock knob. Do not tighten the lock knob at this time.
Fig. 16
20.
Use a square to position the fence exactly 90 degrees relative to the saw blade then tighten the crosscut
fence lock knob.
21.
Check the miter gauge angle indicator. If the reading is not 0 degrees, loosen the indicator lens mounting
screw (245) and adjust the position of the indicator to read 0 degrees. Retighten the mounting screw.
22.
Mount the Fence Extension Support Plate (202) to the bottom of the Fence Extension using four M6 Cap
Screws (203), M6 Lock Washers (115) and M6 Flat Washers (116) from the Fence Extension Support Plate
Mounting Screw Hardware Pack as shown in Fig. 17.
Fig. 17
SLIDING CROSSCUT TABLE INSTALLATION