23 REAR FLuE OuTLET KIT (55/80) ASSEMBLy - ExPLODED VIEW
LEgEND
1. Duct Assembly
2. Plastic Connector
3. Wall Mounting Plate
24 TERMINAL WALL SEAL ASSEMBLy / POSITIONINg
Prior to fitting the flue, the rubber terminal wall seal provided
in the flue pack MUST be fitted to the flue terminal as shown
below in Figure 1.
FIgURE 1
Ensure lip of wall seal is positioned
over step on plastic nose of flue terminal
205862-10137
(note, seal is cut away for clarity)
25 sETTINg ThE REaR FLUE LENgTh - WaLL ThICKNEss OF 115MM TO 442 MM
Wall Thickness X
1. Measure and note wall thickness X. Refer to Frame 1.
2. Add 8mm to dimension X and, measuring from the ring, cut the outer tube
only.
3. To ensure the tube is cut square, mark the flue all the way around.
4. Cut the inner tube to a length 10mm longer to aid engagement, using the
cutting aid provided.
Ideal Logic Heat -
Installation and Servicing
INSTALLATION
Once the flue is installed it is IMPORTANT that the rubber
terminal wall seal is pressed against the outside wall to create
an adequate seal between the flue and wall as shown in
Figure 2.
Step
Wall Seal Lip
1
2
3
FIgURE 2
Measure from
3G9675
Note. If the stand-off frame is used, it is
essential to add 45mm to 'X' the measured
wall thickness when marking the flue (this
will allow for the fitted frame)
Rubber
Terminal
Wall Seal
205862-10072
this
RING
23