IDEAL LOGIC COMBI User Manual

IDEAL LOGIC COMBI User Manual

Electronic timer, 7 day
Hide thumbs Also See for LOGIC COMBI:

Advertisement

back
USERS GUIDE
Electronic Timer, 7 day
LOGIC+ Combi, LOGIC Combi & LOGIC Combi E
24, 30, 35
When replacing any part on this appliance, use only spare parts that you can be
assured conform to the safety and performance specification that we require.
Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.

Advertisement

Table of Contents
loading

Summary of Contents for IDEAL LOGIC COMBI

  • Page 1 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.
  • Page 2 back The national regulations and respective safety instructions are to be observed. Interferences and changes to the device will lead to cancellation of the warranty.
  • Page 3: Table Of Contents

    LOGIC COMBI, LOGIC COMBI E & LOGIC + COMBI Electronic Timer Instructions CONTENTS Timer controls ............4 Setting the Time and Date ........5 Setting the Program..........6,7 Setting the Timer to run in automatic mode ....8 Setting the Timer to be Continuously on....8 Setting the Timer to be Continuously off ....8...
  • Page 4: Timer Controls

    back ELECTrONIC TIMEr CONTrOLS Boiler Lit Display +/- keys Symbol Control Knob for program selection TUES THUR Indication of programmed HOURS Next Day Indication of programmed on time Copy Key Reset Button OK Key...
  • Page 5: Setting The Time And Date

    back SETTING ThE TIME aNd daTE Note. Summer/Winter time automatically updated. Turn the Control Knob to the “TIME/DATE” position Press the keys to change the Hours to the current time and to enter press the Press the keys to change the Minutes to the current time and to enter press the Press the keys to change the...
  • Page 6: Setting The Program

    back SETTING ThE prOGraM Turn the Control Knob to the “PROGRAM” position Press the keys to change the Hours figure for Monday’s 1st On Time and to enter press the Press the keys to change the Minutes figure for Monday’s 1st On Time and to enter press the Press the keys to change the...
  • Page 7 back Press the keys to change the Minutes figure for Monday’s 2nd On Time and to enter press the Press the keys to change the Hours figure for Monday’s 2nd Off Time and to enter press the Press the keys to change the Minutes figure for Monday’s 2nd Off Time...
  • Page 8: Setting The Timer To Run In Automatic Mode

    back SETTING ThE ELECTrONIC TIMEr TO ruN IN auTOMaTIC MOdE (using the programmed on and off times) Turn the Control Knob to the ‘RUN’ position SETTING ThE ELECTrONIC TIMEr TO BE CONTINuOuSLy ON Turn the Control Knob to the ‘CONT ON’...
  • Page 9: Setting + Hours

    back SETTING hOurS Note. Use of the ‘+ Hours’ function will ensure the boiler operates continuously for up to 3 hours. If used during an off period, the boiler will then operate for up to 3 hours. If used during an on period less than 3 hours prior to an off period, it can extend the on time. Turn the Control Knob to the “+ HOURS” position Press the keys to set the required + Hours time and to enter press the Turn the Control Knob to the required operating condition: RUN, or CONT OFF...
  • Page 10: Advanced Features

    back adVaNCEd FEaTurES A. HOLIDAY MODE Press the key for more than 3 seconds Press the keys to change the Year to the year the holiday will start and to enter press the Press the keys to change the Month to the month the holiday will start (note, January = 1) and to enter press the...
  • Page 11 back adVaNCEd FEaTurES B. TIMED PRE-HEAT When Domestic Hot Water preheat is switched on at the boiler control the boiler will preheat during the timed on central heating periods so as to provide more efficient water delivery. This function is disabled when the preheat switch is set to off.
  • Page 12: Error Description

    back adVaNCEd FEaTurES D. EngLIsH LAnguAgE ERROR DEsCRIPTIOn Boiler fault codes are identified on the display in plain English, they are also supported with a suggested corrective action to aid diagnostics. BOILEr ErrOr COdE ErrOr dISpLay COrrECTIVE aCTIONS L1 - OVERHEAT LOCKOUT 1.
  • Page 13 back adVaNCEd FEaTurES L6 - FAULT 8 1. CONTACT INSTALLER F1 - LOW WATER PRESSURE 1. FILL SYSTEM TO 1.0 BAR 2. BLEED RADIATORS F2 - FLAME LOSS 1. CHECK OTHER GAS APPLIANCES WORK F3 - FAN FAULT 1. CONTACT INSTALLER F4 - FLOW THERMISTOR FAULT 1.
  • Page 14 back...
  • Page 15 back...
  • Page 16 November 2011 UIN 204773 A03 Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice. Ideal Boilers Ltd., P.O. Box 103, National Ave, Kingston Upon Hull, HU5 4JN.