Installation instructions
US
14
CA
Special requirements for alcove or closet installation
The minimum ventilation clearance between the washer and adjacent walls or other surfaces is:
1" (25 mm) minimum either side and front
3" (75 mm) minimum rear
Consideration must be given to providing adequate
clearance for installation and servicing.
The minimum vertical space required from floor
to overhead shelves, cabinets, ceilings etc is
58" (1470 mm).
Closet doors must be louvered or otherwise
ventilated and have at least 60 square inches
of open area for a washer only, or if the closet
contains both a washer and dryer, doors must
contain at least 120 square inches of open area
equally distributed.
Caution!
Do not install this appliance in a closet with a solid door.

Mobile home installation

Installation must conform to the STANDARD FOR MOBILE HOMES, ANSI A119.1 and NATIONAL
MOBILE HOME CONSTRUCTION & SAFETY STANDARDS ACT OF 1974 (PL93-383).

Grounding instructions

This appliance must be grounded. In the event of malfunction or break down, grounding will
reduce the risk of electric shock by providing a path of least resistance for electric current. This
appliance is equipped with a cord that has an equipment-grounding conductor and a grounding
plug. The plug must be plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
Specification subject to change without notice.
Additional instructions
Cleaning your washer
Due to the water and energy efficient nature of your machine, regular cleaning of the inside of
your washer is necessary and important. Please refer to page 37 for more information.
Fig.12 Louvered door Washer & Dryer
60 Sq. In
(388 Sq. cm)
60 Sq. In
(388 Sq. cm)