7

BURNER

Variations in nozzle throughput, flue type & draught, oil viscosity etc. may
KEROSENE SETTINGS
Output
Range
Kw / Btu
Kw.
Mid
C20
70K
Max
Mid
C26
90K
Max
Mid
C35
120K
Max
Mid
C44
150K
Max
Mid
C58
200K
Max
Mid
C73
250K
Max
Variations in nozzle throughput, flue type & draught, oil viscosity etc. may give results differing from these laboratory performance figures.
KEROSENE SETTINGS
Output
Range
Kw / Btu
Kw.
Mid
C20
70K
Max
Mid
C26
90K
Max
Mid
C35 120K
Max
The above performance figures are based on ideal laboratory test conditions. Air shutter settings above may need to be revised to take into consideration difference in resistances between
conventional and balanced flue installations, air temperature and Nozzle tolerance. Use flue gas analyser to achieve optimum results.
Danfoss ES Nozzles are a kerosene nozzle have a tolerance of +- 5%. Danfoss S + H Nozzles are a Diesel nozzle have a tolerance of +- 15% when used with Kerosene.
Air Box 1
Air Box 2
Riello RDB 2.2 Range Burner Settings (K).
give results differing from these laboratory performance figures.
for Firebird C Boiler Range Using RDB 2.2 Burner
Head
Nozzle
Type
Size-Type
T1
0.50 80˚ES
T1
0.60 80˚ES
T3
0.65 80˚ES
T3
0.75 80˚ES
T3
0.85 80˚ES
T3
0.85 80˚ES
T5
1.25 60˚ES
T5
1.25 60˚ES
Comb.
1.50 60˚ES
Comb.
1.50 60˚ES
Comb.
1.75 60˚ES
Comb.
1.75 60˚ES
Ecoflam Max 4 Burner Settings (K).
for Firebird C Boiler Range Using Ecoflam Max 4 Burner
Head
Nozzle
Type
Size-Type
BFB 01.004/004 0.50 80˚ES
BFB 01.004/004 0.50 80˚ES
BFB 01.154/001 0.65 80˚ES
BFB 01.154/001 0.75 80˚ES
BFB 01.154/001 0.85 80˚ES
BFB 01.154/001 1.00 80˚ES
T1 Part No. 7137
RDB T1
Hole to aid
Top
photocell
4mm
holes
Clearance for
Dia. 18mm
electrodes
Pump
Air
Comb
Pressure bar
Head
9 bar
1.8
-
7.8 bar
2.8
-
9 bar
3.4
-
10 bar
4.0
-
9 bar
5.6
-
10 bar
5.9
-
7.5 bar
5.0
-
8.5 bar
5.5
-
8 bar
3.0
2.0
10 bar
4.9
2.0
8 bar
0.0
2.0
10 bar
5.5
2.5
Pump
Air
Comb
Pressure bar
Head
9 bar
2.5
10 bar
3.9
9 bar
4.8
10 bar
5.3
8.5 bar
6.2
8.5 bar
7.5
T3 Part No. 7139
RDB T3
Hole to aid
Top
light detection
Clearance for
Dia. 20mm
electrodes
55
Firebird Enviromax Condensing Range
Fg. ˚C
CO2
Smoke
70 avg. 12.0%
75 avg. 12.0%
75 avg. 12.0%
85 avg. 12.0%
90 avg. 12.0%
95 avg. 12.5%
65 avg. 12.0%
65 avg. 12.0%
70 avg. 12.0%
70 avg. 12.0%
70 avg. 12.0%
80 avg. 12.0%
Override settings in burner manual.
Fg. ˚C
CO2
Smoke
-
70 avg. 12.0%
-
75 avg. 12.5%
-
75 avg. 12.0%
-
85 avg. 12.0%
-
90 avg. 12.0%
-
95 avg. 12.5%
T5 Part No. 7140
RDB T5
Top
photocell
Dia. 23mm
Air
No
Box
0-1
1
0-1
1
0-1
1
0-1
1
0-1
1
0-1
1
0-1
1
0-1
1
0-1
1
0-1
1
0-1
1
0-1
1
Fan
No
Scoop
0-1
No
0-1
No
0-1
Yes
0-1
Yes
0-1
Yes
0-1
Yes
Hole to aid
photocell
light detection
Clearance for
electrodes