Liebert NX User Manual page 97

40-200kva, 480v, 60hz
Hide thumbs Also See for NX:
Table of Contents

Advertisement

Table 31
Descriptions of UPS menus and data window items (continued)
Menu Type
Item Type
Sout (kVA)
Pout (kW)
System
Qout (kVAR)
Single unit, no parallel data
Battery voltage (V)
Battery current (A)
Battery temperature (°C)
Battery
Remain Time Min.
Battery boost charging
Battery float charging
Battery disconnected
Records
(History Log)
Language
(choices for text displayed)
Display contrast
Date format set
Date & time
Comm1 baud rate
Comm2 baud rate
Comm3 baud rate
Communication address
Communication mode
Settings
Settings
Callback times
Phone No.1
Phone No.2
Phone No.3
Command password
Audible Alarm
Battery maintenance test
Battery capacity test
System test
Command
(start / stop
Stop testing
battery &
system
tests)
Freshening Charge
Stop Freshening Charge
Modem Auto-answer
enable
Battery Commission
UPS version
Version
UPS model
®
Liebert
NX
Sout: Apparent power
Pout: Active power
Qout: Reactive power
When configured as a single unit, UPS has only native load, no system load.
Battery bus voltage
Battery bus current
Internal battery temperature °C
Battery run time remaining.
Battery is boost charging.
Battery is float charging.
Battery is not connected.
Displays all records in the history log.
User may select any of 12 languages for LCD text.
Adjust the LCD contrast
Choose the format for date display: M/D/Y, D/M/Y, M/D/Y, Y/M/D
Set the date and time
Communication baud rate setting for Liebert IntelliSlot 1
Communication baud rate setting for Liebert IntelliSlot 2
Communication baud rate setting for Liebert IntelliSlot 3
This setting is applicable to RS485 communication mode.
Communication Mode Setting
When Liebert IntelliSlot 1 Communication mode is Modem, this parameter
sets the number of times a number is redialed to send an alarm notification.
When Liebert IntelliSlot 1 Communication mode is Modem, this is the first
phone number to be dialed (to send an alarm notification).
When Liebert IntelliSlot 1 Communication mode is Modem, this is the second
phone number to be dialed (to send an alarm notification).
When Liebert IntelliSlot 1 Communication mode is Modem, this is the third
phone number to be dialed (to send an alarm notification).
User can modify the command password.
User can Enable and Disable the UPS audible alarm.
This test performs a partial discharge of the battery to obtain a rough estimate
of the battery capacity. Load must be between 20% and 80%.
This test performs a full discharge of the battery to obtain a precise measure of
the battery capacity. Load must be between 20% and 80%.
This is a self-test of the UPS. When the user activates this function, a pop-up
window appears about 5 seconds later to show the results.
Manually stops a battery maintenance test, battery capacity test or system
test.
Allows a temporary Equalize charge for the batteries. This charge is
configurable for 1 to 36 hours.
Manually stops a Freshening Charge.
Manually enable the modem's auto-answer function.
Resets the UPS battery detection logic after new/fresh batteries are installed.
Provides UPS firmware version numbers for the inverter, rectifier and software
display board.
Provides UPS model information—for example, 480V-60Hz.
87
Operator Control and Display Panel
Explanation