FUSING UNIT REMOVAL

9.3 FUSING UNIT REMOVAL

CAUTION
Allow time for the unit to cool before doing the following procedure.
[C]
1. Turn off the main switch and unplug the machine.
2. Open the front cover.
3. Remove the stopper bracket [A] (1 screw).
4. Hold the fusing unit cover [B] while pushing the release lever [C] to the left, and
pull out the fusing unit until it stops.
5. Push the release lever again, and remove the fusing unit completely.
NOTE: Before completely removing the fusing unit, support the bottom of the
fusing unit.
A217R511.CDR