Chapter 2 Convenient Features
(2)
Power Control Configuration submenu
From the Server menu, move the cursor to Power Control Configuration and then press the <Enter> key to
show its submenus.
For details about the options, see the table below.
AC-LINK
Power ON Delay Time Mode
Delay Time
Standby Power Save
Option
Parameter
Stay Off
[Last State]
Power On
[Manually Setting]
Random
[45]-600
[Disabled]
Enabled
Express5800/R120d-1E, R120d-2E Maintenance Guide
Descriptions
Specify AC link feature. Specify how the DC power
state should be when the AC power is supplied again
after loss of power. (See the table below)
Select a method to specify the delay time before
powering on DC power. Available options are:
"User-specified value" or "random value".
This option is selectable when Power On or Last
State is specified in AC-LINK.
Specify the delay time.
The minimum configurable time may differ from
factory-set value.
The minimum configurable time is displayed when
executing Load Setup Defaults.
This menu is selectable when Manually Setting is
specified for Power ON Delay Time Mode.
Enable or disable the feature that saves the standby
power in standby state. If this option is set to Enabled,
the AC-LINK setting is fixed to Power On
automatically and cannot be changed. With AC power
off state, management, monitoring, and power-on of
server are disabled on remote site. Powering on the
server is available only by pressing the POWER switch
on the server.
If AC-LINK setting is changed from the remote site
with this option being set, you need to press the
POWER switch twice to power on the server.