NEC R120d-1E N8100-1954F Maintenance Manual page 84

Express5800 series
Hide thumbs Also See for R120d-1E N8100-1954F:
Table of Contents

Advertisement

Chapter 2 Convenient Features
Thermal Sensor
Check previous System Config
BMC IRQ
Post Error Pause
Memory Error
Power Switch Inhibit
CLI SETUP
84
Option
Disabled
[Enabled]
[Disabled]
Enabled
Disabled
[IRQ 11]
Disabled
[Enabled]
Halt
[Boot]
[Disabled]
Enabled
[Disabled]
Enabled
Express5800/R120d-1E, R120d-2E Maintenance Guide
Parameter
Enable or disable the thermal sensor
monitoring feature.
If this option is set to Enabled and when
abnormal temperature is detected, stops
POST before OS starts and waits until the
temperature becomes normal.
Enable or disable the feature to detect
system configuration change.
If this option is set to Enabled and the
system configuration differs from the
previous boot, POST stops before OS
booting and displays confirmation message
whether to continue booting. At this time,
POST pauses until user's response is made.
Specify whether to allocate interrupt lines for
BMC (Baseboard Management Controller).
Enable or disable the feature to suppress OS
booting when POST detects an error, until
user's response is made.
When set to Disabled, continues OS booting
regardless of user's response even if an error
is detected during POST.
Enable or disable the feature to suppress OS
booting when POST detects a memory
degradation error, until user's response is
made. This option is valid only when POST
Error Pause is set to Enabled.
Even if this option is set to Boot, POST stops
to suppress OS booting if all of thememory
resources are degraded.
Enable or disable the POWER switch inhibit
feature.
Enable or disable the Command Line
Interface SETUP feature. When this option is
set to Enabled, the operation of SETUP is
changed to use Command Line Interface. To
switch back to the menu operation, set this
option to Disabled.
For command details, execute HELP
command at CLIP SETUP prompt. If the
system is connected with bootable devices
exceeding a certain number of devices, an
error message "Failed to get Boot Variable
data" appears on command line, and the
Boot menu is not displayed or changing
parameter is disabled. In this case, reduce
the number of bootable devices by
disconnecting any USB devices not required
for bootup, or change parameter [Option
ROM Scan] for onboard device or PCI slot to
[Disabled.]
1. System BIOS
(2/2)
Descriptions
[
]: Factory setting

Advertisement

Table of Contents
loading

Table of Contents