Chapter 3 Appendix
[Description]
A checksum error was detected in SROM data.
[Recommended action]
Unplug the power cord of server, wait for 30 seconds, and reboot the server.
If it does not resolve your problem, contact your sales representative.
C061: 1st SMBus device Error detected.
C062: 2nd SMBus device Error detected.
C063: 3rd SMBus device Error detected.
C064: 4th SMBus device Error detected.
C065: 5th SMBus device Error detected.
C066: 6th SMBus device Error detected.
[Description]
An error was detected on SMBus.
[Recommended action]
Unplug the power cord of server, wait for 30 seconds, and reboot the server.
If it does not resolve your problem, contact your sales representative.
C103: BMC core hardware failure.
[Description]
A BMC error was detected.
[Recommended action]
Unplug the power cord of server, wait for 30 seconds, and reboot the server.
If it does not resolve your problem, contact your sales representative.
C104: BMC IBF or OBF check failed.
[Description]
An error was detected while accessing BMC.
[Recommended action]
Unplug the power cord of server, wait for 30 seconds, and reboot the server.
If it does not resolve your problem, contact your sales representative.
C105: BMC SEL area full.
[Description]
There is not enough space to store IPMI system event log.
[Recommended action]
Launch Offline Tools and erase IPMI system event logs.
If it does not resolve your problem, contact your sales representative.
C10B: BMC operational code corrupted.
134