Chapter 1 Maintenance
[?]
DISK LED flashes
DISK LED flashes frequently even while the Hard Disk Drive is not accessed.
When Patrol Read is running, the DISK LED flashes even if the Hard Disk Drive is not being accessed. If
SATA Hard Disk Drive is used, the DISK LED may stay on.
[?]
When N8190-153/154 is used, the names of the Fibre Channel controllers may appear with different names
on Device Manager
When N8190-153/154 is used in Windows Server 2008 R2 or Windows Server 2008, a different controller
name may be displayed per controller in Device Manager. It is not a problem in operating the system.
To display correct controller name, run the following command stored in the EXPRESSBUILDER DVD and
reboot the system.
Windows Server 2008 R2/Windows Server 2008 x64 Edition:
EXPRESSBUILDER DVD:\023\win\winnt\ws2008x64\elxstor\friendlyname.exe
Windows Server 2008:
EXPRESSBUILDER DVD:\023\win\winnt\ws2008\elxstor\friendlyname.exe
[?]
Physical device is not correctly displayed on Universal RAID Utility:
→ If you use LSI Embedded MegaRAID, a part of information on a physical device is not correctly
displayed on Universal RAID Utility.