CLEANING THE SUCTION TUBE

Whenever suction seems to be unsatisfactory, check that the suction tube (1) is not
obstructed. If necessary clean with a jet of water as follows:
1. Detach the aspiration tube from the seat on the recovery tank.
2. Clean it with a water jet introduced from the side where it is connected to the tank.
3. Reassemble everything, carrying out the above-mentioned operations in the
reverse order.
WARNING: This operation must be carried out using gloves to
protect against contact with dangerous solutions.

CLEANING THE SOLUTION TANK

At least once a week, it is necessary to carefully clean the solution tank in order to keep
the machine in perfect state:
1.
Disconnect the clean water drainage pipe (1) from its housing on the left side of the
machine, unscrew the cap and empty the tank.
2.
Remove the plug from the solution tank refill opening.
3.
Rinse the inside of the tank with a jet of water.
4.
Close the drainage pipe with the cap and put it in place.
5.
Close the tank by placing the filter and the cap.

CLEANING THE RECOVERY TANK

1. Disconnect the tube (1) from its seat, unscrew the drainage cap and empty the
recovery tank.
WARNING: This operation must be carried out using gloves to
protect against contact with dangerous solutions.
2. Raise the cap (2) until the hook is secured to the prop (3) of the recovery tank.
3. Check the filter inside the cover (4) is clean and, if necessary, loosen the cover fixing
screws and carefully rinse the filter.
4. Clean and rinse the recovery tank and the suction pipe (connecting pipe between the
squeegee and the tank).
5. Reposition the cap on the drainage tube and lower the suction cap. To lock the prop (3)
just slightly raise the cap, release the prop (3) and lower the cap up to close it.