After re-installing the timer assembly through the
firebox access door, re-attach the timer assembly to
the air chamber cover using a Phillips head screw
driver. See Figure 4.19.
•
Attach the linkage upper arm to the lower linkage
arm.
Figure 4.20 Timer Box Installed
7. Timer Removal & Replacement
•
Loosen set screw on timer, remove two screws and
remove timer. See Figure 4.21.
Remove
2 screws
Loosen Set Screw
Figure 4.21 Timer
24
Remove Timer
Quadra-Fire • 7100 FP Owner's Manual • 433-3600 • Rev J • 09/21/15
•
Install new timer using same two screws. It is very
important that the D cut side of the timer shaft is
facing the opposite side of the linkage timer arm.
See Figure 4.22.
D cut side of timer shaft must face
away from the Linkage Timer Arm
Figure 4.22 D Cut on Shaft
•
Place linkage control arm over timer shaft and tighten
set screw, Figure 4.23.
Tighten set screw
Figure 4.23 Linkage Control Arm Installed
•
Rotate linkage control arm into final position and
re-attach to mounting plate. Note that the D cut is now
facing the linkage timer arm. Re-attach the linkage
timer arm, Figure 4.23.
•
Retun to Timer Assembly Replacement, Section
4.B.6.