Timer Assembly Replacement - Quadra-Fire 7100FP-GD-B Owner's Manual

Hide thumbs Also See for 7100FP-GD-B:
Table of Contents

Advertisement

Removing the fan
-
Unplug the wire harness.
-
Lift fan from locating pins and remove (Figure 4.9).
Repeat for second fan if necessary.
-
Connect new fan wires to wire harness.
-
Before installing the fan, make sure the grommets
are tightly in place. Insert the right fan and place
over the two locating pins. Repeat for other fan.
Figure 4.10
-
Re-install bottom panel or firebox access panel
in reverse order as described above.
-
Replace the brick that was removed.
-
Re-install the fascia and both knobs.
-
Re-install both doors and hinge pins.
-
Reconnect the power.
Remove
nut and lift
out fan
Figure 4.9
Fan Motor
Figure 4.10 Installing Fans
22
Unplug wire
harness before
removing fan
Quadra-Fire • 7100 FP Owner's Manual • 433-3600 • Rev J • 09/21/15

6. Timer Assembly Replacement

CAUTION! Risk of Shock! Disconnect power by
turning off circuit breaker BEFORE servicing.
Remove both doors, outside air knobs, fascia, and
brick.
Remove two Phillips head screws and pry open
access door in the bottom of the fireplace with a flat
head screwdriver. See Figure 4.11.
Figure 4.11 Open Access Door
Remove two screws and take off access cover shown
in Figure 4.12.
Figure 4.12 Access Cover
NOTICE: The timer assembly included in this kit comes
with the air chamber cover attached (Figure 4.13).
You will need to disconnect air chamber cover from
timer assembly before installing in the fireplace. Set
screws aside for later use. See Figure 4.14 .
Air Chamber Cover is
attached to Timer Assembly
Figure 4.13 Timer Assembly with Air Chamber Cover
(Linkage arm is not included in the kit)
Remove 2 screws and
pry open access door.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7100fp-nl-b

Table of Contents