Removing the fan
-
Unplug the wire harness.
-
Lift fan from locating pins and remove (Figure 4.9).
Repeat for second fan if necessary.
-
Connect new fan wires to wire harness.
-
Before installing the fan, make sure the grommets
are tightly in place. Insert the right fan and place
over the two locating pins. Repeat for other fan.
Figure 4.10
-
Re-install bottom panel or firebox access panel
in reverse order as described above.
-
Replace the brick that was removed.
-
Re-install the fascia and both knobs.
-
Re-install both doors and hinge pins.
-
Reconnect the power.
Remove
nut and lift
out fan
Figure 4.9
Fan Motor
Figure 4.10 Installing Fans
22
Unplug wire
harness before
removing fan
Quadra-Fire • 7100 FP Owner's Manual • 433-3600 • Rev J • 09/21/15
6. Timer Assembly Replacement
CAUTION! Risk of Shock! Disconnect power by
turning off circuit breaker BEFORE servicing.
•
Remove both doors, outside air knobs, fascia, and
brick.
•
Remove two Phillips head screws and pry open
access door in the bottom of the fireplace with a flat
head screwdriver. See Figure 4.11.
Figure 4.11 Open Access Door
•
Remove two screws and take off access cover shown
in Figure 4.12.
Figure 4.12 Access Cover
NOTICE: The timer assembly included in this kit comes
with the air chamber cover attached (Figure 4.13).
•
You will need to disconnect air chamber cover from
timer assembly before installing in the fireplace. Set
screws aside for later use. See Figure 4.14 .
Air Chamber Cover is
attached to Timer Assembly
Figure 4.13 Timer Assembly with Air Chamber Cover
(Linkage arm is not included in the kit)
Remove 2 screws and
pry open access door.