Checking Disk Status Leds; Replacing A Failed Disk Drive - Promise Technology SmartStor DS4600 Product Manual

Direct-attached storage (das) enclosure
Hide thumbs Also See for SmartStor DS4600:
Table of Contents

Advertisement

SmartStor DS4600 Product Manual

Checking Disk Status LEDs

The disk status LEDs report the condition of the disk drives:
Blue – Normal disk drive function
Amber – Rebuilding to this disk drive
Red – Failed disk drive
Dark – No disk drive is installed
The disk status LEDs are also dark when the drives are powered down during
system stand-by.
Figure 1. SmartStor Disk and System Status LEDs

Replacing a Failed Disk Drive

If a disk drive fails, the Disk Status LED is red. See Figure 1. If the disk drive
belongs to a RAID Volume, the Volume goes Critical or Offline.
Replace the failed disk drive with a new disk drive of the same or slightly greater
capacity. You do not have to power down the SmartStor.
1.
Open the SmartStor's front door.
2.
Pull out the drive carrier with the failed drive.
3.
Remove the failed disk drive from the drive carrier.
4.
Install a new disk drive into the carrier.