3.4

Changing the batteries

L L L L
CAUTION:
Risk of burns - Do not come in contact with the acid from the batteries.
See for a good ventilation of the battery compartment.
The battery shall be changed by trained personel.
3.5

Battery connections

1
1
3
2
4
Adjust the length of the footrests as follow:
1. Remove the screw Ⓒ.
2. Adjust the length of the footrest to a
comfortable length according table 7.
3. Tighten the screw Ⓒ
Check that the footrests are positioned
identically on both sides.
The battery can be changed according
following steps.
1.
2.
3.
4.
5.
6.
7.
8.
9.
3
Page 30
properly.
Remove the seat frame (paragraph 2.10)
Disconnect all the wires on the batteries.
Lift the first battery
housing
.
Slide the second battery
take it out the battery housing
Take the new batteries.
Place the first battery
housing
and push it backwards.
Place the second battery
housing
.
Connect all the wires to the batteries.
Replace the seat frame (paragraph 2.10)
1 = Battery 12 V
2 = Thermal safety fuse 30A
3 = Battery connection plug
4 = Plug operator control
= Black cable
= Red cable
Navix
2012-10
out the battery
forward and
.
in the battery
in the battery

Advertisement