Setting
Alarm enable
condition
Before Detected/
After Detected
Executing
Commands for
Detection
Sensor deactivation
time
Note
Configure alarm/sensor detection after an alarm/sensor has been attached to
the camera.
Setting alarm/sensor detection without an alarm/sensor causes a malfunction.
Specify Alarm enable condition ([Status: Open (High)], [Status:
GND], [Rising : GND to Open (High)] , [Falling : Open (High) to
GND], [Rising and Falling]).
• Specify the alarm enable condition after checking the alarm
specification.
• [Rising : GND to Open (High)] is selected automatically
when [Sensor] is selected.
Specify the time before an alarm/sensor is detected or after an
alarm/sensor is detected.
You can specify commands that execute for alarm detection.
You can configure commands in [Detection Commands] page
(see page 34).
To limit unnecessary continuous detection, set the deactivation
time between detections.
Description