C28" (P1655) Stv Actuator Circuit Malfunction - Suzuki GSX-R1000K5 Service Manual

Table of Contents

Advertisement

"C28" (P1655) STV ACTUATOR CIRCUIT MALFUNCTION

DETECTED CONDITION
The operation voltage does not reach the STVA.
ECM does not receive communication signal from
the STVA.
STVA
B
P
G
W/BI
INSPECTION
Step 1
1) Lift and support the fuel tank. (5-3)
2) Remove the air cleaner cover. (2-4)
3) Check the STVA lead wire coupler for loose or poor contacts.
4) Turn the ignition switch ON to check the STV operation.
(STV operating order: Full open → 95% open)
Is the operating OK?
YES
Go to Step 2.
• Loose or poor contacts on the STVA coupler
• Open or short circuit in the B/Lg, P/W, W/B or
NO
Green wires
• If wire and connection are OK, go to Step 2.
5) After repairing the trouble, clear the DTC using SDS tool.
(4-27)
POSSIBLE CAUSE
• STVA malfunction
• STVA circuit open or short
• STVA motor malfunction
B/Lg
P/W
G
W/B
1
1
FI SYSTEM DIAGNOSIS 4-65
ECM
STVA. 1B
STVA. 1A
STVA. 2B
STVA. 2A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gsx-r1000