Alarm Output Configuration; Figure 14. Alarm Output Configuration Screen; Table 15. Alarm Output Definitions - Canoga Perkins 2370 User Manual

High-speed universal fiber optic modem universal chassis system
Table of Contents

Advertisement

4.9

Alarm Output Configuration

Use the Alarm Output Configuration screen to set any or all alarms to Major, Minor, or Off. See
Figure 14 and Table 15.
To configure alarms, follow these steps:
1. From the System Configuration menu type 4, "Alarm Output Configuration," and press <Enter>.
The Alarm Output Configuration screen appears.
2. Type the number for the alarm you want to set and press <Enter>.
3. Press <Space> to cycle to Major, Minor, or Off, and press <Enter>.
4. To return to the System Configuration menu, press <Esc>.
-------------------ALARM OUTPUT CONFIGURATION----------------------------
1) Factory Defaults
2) LOS/CLS Alarm
3) SQL Alarm
4) Configuration Alarm
5) Power/Fan Alarm
6) Power-On Self Test Alarm
7) BERT Alarm

Figure 14. Alarm Output Configuration Screen

Table 15. Alarm Output Definitions

Alarm
1) Factory Defaults
2) LOS/CLS
3) SQL
4) Configuration
5) Power/Fan
6) Power-On Self Test Modem failed when power was turned on; default is Major
7) BERT
4-10
Reset all alarms to factory defaults, for values, see Figure 14
Loss of Signal (electrical)/Composite Loss of Signal (optical); one or
both received signals fail; default is Off
Squelch (for received signal); default is Off
Setup errors, including mismatches with other modems; default is Off
Power is low or fan is off; default is Minor
Bit Error Rate Test (BERT) detects data errors; default is Off
Model 2370 Model User Manual
Off
Off
Off
Minor
Major
Minor