ABORt

ABORt
:AFANalyzer
:WACLeakage
:WBERror
:WCPower
:WTPower
:WWQuality
"Diagram Conventions" on page 168
ABORt[:ALL]
Function
Stops all measurements that are active.
If the trigger arm is set to single, the measurements will go to the idle state.
If the trigger arm is set to continuous, the measurements will re-arm and initiate again.
Setting
Range
• AFANalyzer - Audio Frequency measurements
• WACLeakage - Adjacent Channel leakage
• WCPower - Channel Power measurement
• WBERror - Loopback Bit Error Ratio measurement
• WTPower - Thermal Power measurement
• WWQuality - Waveform Quality measurement
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"ABORT:ALL" !Aborts all active measurements in progress.
[:ALL]
S:\Hp8960\E1963A WCDMA\3.2 release\Reference Guide\Chapters\wcdma_hpib_abort.fm
ABORt