Figure 32: Lateral alignment of the needle bar
Setting steps
1. Set the stitch length to 0.
2. Put the handwheel into the 90° position ( page 20).
3. Loosen the screw (1).
4. Loosen the screws (2).
5. Loosen the screws (3).
6. Loosen the screw (8).
7. Move the needle bar guide (7) laterally so that the needle bar (4), sewing
8. Tighten the screws (1), (2), (3), (8).
48
(1) - Screw
(2) - Screws
(3) - Screws
(4) - Needle bar
foot bar (5) and presser foot bar (6) are all in a line.
Aligning the needle bar linkage
(5) - Sewing foot bar
(6) - Presser foot bar
(7) - Needle bar guide
(8) - Screw
Service instructions 967 - 00.0 - 12/2014