Specification; Standard Values For Burner Settings; Additional Information - Viessmann VITOFLAME 200 Service Instructions Manual

Oil burner
Hide thumbs Also See for VITOFLAME 200:
Table of Contents

Advertisement

Additional information

Specification

Rated output
kW
Type of burner
Type test no.
acc. to DIN EN 267
Voltage
V
Frequency
Hz
Motor speed
rpm
Version
Oil pump
Litres/h
output
Connections
Suction and return
R (female thread)
line on oil hoses
line on oil hoses
(part of standard
delivery).

Standard values for burner settings

Please note:
Check whether service instructions are valid for boiler concerned (see notes on applicability, page 2 and serial no. on
burner type plate).
Rated output
Oil burner nozzle
*1
Make
Fluidics
Make
Danfoss
*2
Oil pressure approx.
Oil flow rate
Air damper setting
Position of air damper
see page 7
Blast tube connection
setting
Position of setscrew
see page 7
*3
Static burner pressure
Position of test nipple
see page 7
Aluminium deflector
of sensor plate
No. of plugs remaining
in deflector
*1
The requirements laid down for the certificate of environmental excellence were verified only with the nozzles shown.
*2
Due to nozzle tolerances and varying oil characteristics, the oil pressure may vary from that indicated by the values shown.
*3
To check the burner settings.
22
15
18
VEK I 1
VEK I 1
kW
15
Type
60ºSF
60ºSF/
60ºHF
Gph
0.40
0.45/0.50
Type
Gph
bar
9.0
kg/h
1.40
Litres/h
1.65
7.5
mm
3.0
mbar
3.2 3.6
3.2 3.6
0
22
27
VEK I 1
VEK I 1
5G971/2001S
230
50
2 800
single stage
45
e"
18
22
27
60ºHF
45ºSF
0.60
0.75
/
9.0
9.0
8.5
1.68
2.06
2.53
1.98
2.42
2.97
8.0
8.5
10.0
3.0
5.0
8.0
3.2 3.6
3.0 3.3
0
0
2
33
40
VEK I 1
VEK I 2
VEK II 1
5G972/2001S
33
40
45ºSF
1.00
60ºSR
0.85
9.0
10.0
3.09
3.74
3.63
4.40
13.5
16.5
10.0
8.0
2.5 3.0
2.5 3.0
3.2 3.7
0
0
50
63
VEK II 2
50
63
60ºS
80ºH
1.25
1.50
11.5
10.5
4.68
5.89
5.50
6.93
17.0
25.0
10.0
14.0
2.5 3.0
0
0