Displaying / Modifying Control Parameters - Wolf CGB-11 Installation Instructions Manual

Gas fired condensing boilers
Hide thumbs Also See for CGB-11:
Table of Contents

Advertisement

Modifications must only the carried out by a
NB
recognised heating contractor or by Wolf cu-
stomer service.
Incorrect operation can lead to system faults.
NB
Please note when using parameter GB 05 or
A09 (frost protection/outside temperature), that
frost protection is not safeguarded if you set
temperatures lower than 0 °C. This can lead to
heating system damage.
The control parameter can be modified or displayed via controller with eBUS capability. For procedures, check the operating in-
structions of the relevant accessories.
Settings of column 1 are suitable for control accessories ART and AWT.
Settings of column 2 are suitable for Wolf control systems with BM (programming unit)
1
2
Parameter
GB01
HG01
Flow temperature hysteresis
HG02
Lower fan speed
Min. fan speed in %
HG03
Upper fan speed DHW
Max. fan speed in % for DHW
GB04
HG04
Upper fan speed central heating
Maximum fan speed in % for central heating
GB05
A09
Frost protection outside temperature
With connected outside temperature sensor and
insufficient temperature pump ON
GB06
HG06
Heating circuit pump mode
0 → Pump ON in winter mode
1 → Pump ON when the burner is ON
GB07
HG07
Heating circuit pump run-on time
Heating circuit pump run-on time in heating mode in min.
Heating circuit pump run-on time in heating mode in min.
GB08
HG08 or
Maximum set flow temperature
HG22
Applies to heating mode
GB09
HG09
Cycle block
applies to heating mode
HG10
e Bus address
Bus address of boiler (display only)
HG11
DHW quick start-up
Temperature of plate heat exchanger in summer mode
(suitable for combi-boilers only)
HG12
Gas type
not assisted
GB13
HG13
Input E1
Input E1 (24 V)
Various functions can be allocated to input E1.
See chapter „Connection input E1"
GB14
HG14
Output A1 (230VAC)
Various functions can be allocated to output A1.
See chapter „Connection output A1"
GB15
HG15
DHW cylinder hysteresis
Switching differential for cylinder reheating
GB16
HG16
Minimum pump speed, heating mode
GB17
HG17
Minimum pump speed, heating mode
HG21
Minimum boiler water temperature TK-min
28
Displaying/
modifying control parameters
To prevent damage to the heating system, cancel
NB
night setback when outside temperatures fall
below -12 ° C. If this rule is not observed, ice
may form on the flue outlet which may result in
injury to individuals or material losses.
Unit
K
8
%
CGB-11: 27
CGB-20: 27
CGB-24: 30
%
CGB-11: 100
CGB-20: 100
CGB-24: 98
%
CGB-11: 70
CGB-20: 82
CGB-24: 82
°C
2
0
min
1
°C
80
min
7
0
°C
10
0
1
Roomther-
mostat
6
Cylinder pri-
mary pump
5
%
CGB-11: 27
CGB-20: 48
CGB-24: 48
%
CGB-11: 56
CGB-20: 77
CGB-24: 82
°C
20
Factory
min
max
setting
5
30
27
100
27
100
27
100
-10
10
0
1
0
30
40
90
1
30
0
5
10
60
0
1
0
5
0
9
1
30
20
100
20
100
20
90