Host Timeout (1-16711450): Specifies the maximum amount of time
a host can be a member of a multicast group without the Switch
receiving a host membership report. The default is 260 seconds.
Router Timeout (1-16711450): Specifies the maximum amount of
time a route can be a member of a multicast group without the Switch
receiving a host membership report. The default is 125 seconds.
Member Ports: Checked specifies of ports as being connected to
multicast-enabled routers. This will ensure that all packets with such a
router as its destination will reach the multicast-enabled router −
regardless of protocol, etc.

Storm Control

Storm Control function allows the Switch to avoid continues
broadcasting packets causes the performance drop down.
When enabled the ARP Strom Control, the Switch will detect all
incoming data packets, if the Switch received more then 500
broadcast packet within a second, the Switch will stop forward the
broadcasting packets till 5 minutes. If you would not wait for 5
minutes to recover back to the normal process, press the "Unlock
ARP Packet" button to allow the Switch to forward the broadcast
packets.
Figure 39. Storm Control
43