HP StorageWorks 2000 Series Reference Manual page 287

Storageworks 2000 family modular smart array
Hide thumbs Also See for StorageWorks 2000 Series:
Table of Contents

Advertisement

163
Warning
166
Warning
167
Warning
The host FC World Wide Names
(node and port) previously presented
by an offline controller module in this
system are unknown.
This event has two possible causes:
• The online controller module
reporting the event was replaced or
moved while the system was
powered off.
• The online controller module had
its flash configuration (where
previously used WWNs are stored)
cleared.
The online controller module
recovers from this situation by
generating a WWN for the other
controller module based on its own
serial number.
The RAID metadata level of the two
controllers does not match. Usually,
the controller at the higher firmware
level can read metadata written by a
controller at a lower firmware level.
The reverse is typically not true.
Therefore, if the controller at the
higher firmware level failed, the
surviving controller at the lower
firmware level cannot read the
metadata on drives that have failed
over.
A diagnostic test at controller bootup
detected an abnormal operation,
which might require a power cycle to
correct.
Verify the WWN information for
the other controller module on all
hosts that access it.
Update the controller with the
lower firmware level to match the
firmware level on the other
controller.
A service technician must review
the error information returned.

Advertisement

Table of Contents
loading

Table of Contents