6
Informational
or warning
8
Warning
9
Informational
16
Informational
18
Informational
or warning
19
Informational
20
Informational
21
Informational
or warning
23
Informational
Vdisk creation status. This event is
logged as informational if creation
immediately failed, was canceled by
the user, or succeeded. This event is
logged as a warning if creation failed
during initialization.
A drive in a vdisk failed and the
vdisk changed to a critical or offline
state. If a spare is present the
controller automatically uses the
space to reconstruct the vdisk.
A spare disk drive has been used in a
critical vdisk to bring the vdisk back
to a fault-tolerant state. Vdisk
reconstruction starts automatically.
A global spare has been added.
Vdisk reconstruction status. This
event is logged as informational if
reconstruction succeeded, or as a
warning if reconstruction failed.
A rescan has completed.
A firmware update has completed.
Vdisk verification has completed.
This event is logged as informational
if the command fails immediately,
succeeds, or is aborted by the user; or
a warning if the operation fails during
verification.
Vdisk creation has started.
• See "Disk Drive Errors and
Recommended Actions" on
page 300.
• If dynamic spares is enabled,
replace the failed drive. The
system automatically
reconstructs the vdisk.
• If dynamic spares is disabled and
no spare is available, replace the
failed drive and add it as a vdisk
spare to the critical vdisk.