HP StorageWorks 2000 Series Reference Manual page 222

Storageworks 2000 family modular smart array
Hide thumbs Also See for StorageWorks 2000 Series:
Table of Contents

Advertisement

For example:
Event SN
Date/Time
A29856
08-06 09:35:07
A29809
08-04 12:12:05
When reviewing events, do the following:
1. Review the critical/warning events.
Identify the primary events and any that might be the cause of the primary event.
For example, an over temperature event could cause a drive failure.
2. Review the event log for the controller that reported the critical/warning event by
viewing the event log by controller. Locate the critical/warning events in the
sequence.
Repeat this step for the other controller if necessary.
3. Review the events that occurred before and after the primary event.
During this review you are looking for any events that might indicate the cause of
the critical/warning event. You are also looking for events that resulted from the
critical/warning event, known as secondary events.
4. Review the events following the primary and secondary events.
You are looking for any actions that might have already been taken to resolve the
problems reported by the events.
Code
Severity
Controller
33
I
A
65
C
A
Description
Time/date has been changed
Uncorrectable ECC error in
buffer memory address 0x0 on
bootup