Replacing Consumables

Resetting the lamp hours

The projector records how long the lamp is turned on and a message and
indicator notify you when it is time to replace the lamp. After replacing the
lamp, make sure you reset the Lamp Hours from the Configuration menu.
"Reset Menu"
p.122
s
a
Only reset the Lamp Hours after the lamp has been replaced.
Otherwise the lamp replacement period is not indicated correctly.

Replacing the Air Filter

Air filter replacement period

If the message is displayed frequently even though the air filter has been
cleaned, replace the air filter.

How to replace the air filter

The air filter can be replaced even when the projector is suspended from a
ceiling.
a
After you turn off the projector's power and the confirmation
buzzer beeps twice, disconnect the power cord.
b
Open the air filter cover.
Slide the air filter cover operation knob, and open the air filter
cover.
c
Remove the air filter.
Grip the tab in the center of the air filter, and pull it straight out.
d
Install the new air filter.
Press until it clicks into place.