Model
Function
Rated voltage
Rated frequency
Capacity
Nominal power
Max. power
Greatest currency
Air flow
Dry capacity
C.O.P/EER
Model
Fan speed (r/min)(H/M/L)
Output power (W)
Auxiliary electric heater power
Fan capacitor
Fan motor running current
Fan type-piece
Diameter-length (mm)
Evaporator
Pipe diameter
Indoor
Row-fin distance (mm)
unit
Developed area of heat exchanger
(I×H×L)
Swing motor model
Motor power (W)
Fuse (A)
Noise (sound pressure level)
dB(A)
Noise (sound pressure level)
dB(A)
Outline dimension (W/D/H) (mm)
Package dimension (W/D/H) (mm)
Net weight/gross weight (kg)
Cooling
(W)
3200
(W)
1060
(W)
1390
(A)
7.2
(m3/h)
(L/h)
(W/W)
3
KFR-32G/NaA121-E
—8—
PRO AIR 112 IN
Heating
3400
1220
1370
7.4
450
1.2
2.8
1160/1010/890
14
0.12
Cross flow fan-1
Φ97×583
Aluminum fin-copper tube
580mm ×228.6mm×25.4mm
MP24GA
PCB3.15A
42/39/36
52/49/46
770×180×250
855×270×336
8.5/12.5
PRO AIR I109 IN
Cooling
230V
50Hz
2500
730
1246
5.7
450
1.2
3.4
KFR-25G/NaA12F-E
1190/1090/990
14
/
1
0.12
Φ7
2-1.4
2
Transformer 0.2A
42/39/36
52/49/46
Heating
2700
800
1297
6
3.4

Advertisement