Download Print this page

GE PRO AIR 107 Service Manual page 10

Split system air conditioner
Hide thumbs Also See for PRO AIR 107:

Advertisement

Model
Compressor type
Compressor type
Locked rotor current
Compressor running current
Compressor input power
Compressor overload model
Throttling method
Starting mode
Working temperature range
Condenser
Pipe diameter
Row-fin distance (mm)
Developed area of heat exchanger
(I×H×L)
Fan motor speed (rpm)
Motor rated power (W)
Outdoo
Fan motor running current (A)
r unit
Fan capacitor (μf)
Fan type-piece
Fan type-piece
Fan diameter (mm)
Defrosting method
Climate type
Insulation class
Waterproof level
Maximum working pressure of
exhaust side (Mpa)
Maximum working pressure of
exhaust side (Mpa)
Noise (sound pressure level) dB(A)
Noise (sound pressure level) dB(A)
Outline dimension (W/D/H) (mm)
Package dimension (W/D/H) (mm)
Net weight/gross weight (kg)
Refrigerant/refrigerant charge (kg)
Length
Outer
Liquid pipe
diameter
Gas pipe
Maximum
Height
distance
Length
PRO AIR 112 OUT
C-RV133H1A
B210-145-241E
791×508×44
848×320 ×540
878×360 ×600
R410A /1.3
(mm)
(mm)
(m)
(m)
—9—
Rotary type
24
5.25
1125
Capillary
Capacitor
-7~43℃
Aluminum fin-copper tube
Φ9.52
2-1.4
830
30
0.26
2.5
/
Axial flow fan-1
Φ400
Auto
T1
I
IP24
3.8
1.2
56
66
30/34
4
Φ6
Φ9.52
5
10
PRO AIR 109 OUT
EU1011DV
33.5
4
628
4CYC11233
2-1.4
645×508×44
830
30
0.3
2.5
Φ400
54
64
848×320 ×540
878×360 ×600
41/43
R410A /1.2

Advertisement

loading