Operation procedures/pictures
Disassembling the motor and motor support
SCREW off 4 tapping screws that fix the motor to
take out the motor. Unscrew 2 tapping screws for
fixing the motor bracket, pull it upward, and take
out the motor bracket as shown in Fig.8-31.
Disassembling four-way valve
Unscrew the fixing nut of the four-way valve coil
and remove the coil. Wrap the four-way valve
with wet sponge and weld off the four welding
spots on the four-way valve to take off the
four-way valve. The welding process should be
performed as quick as possible, ensure that the
wrapped spun cotton should be moistened all
along; ensure that the pin cords etc. of
compressor must not be burnt out by thin flame
as shown in Fig.8-32.
Capillary assembly
Weld off the welding spots between the capillary
assembly and other pipeline connection and take
off the capillary assembly as shown in Fig.8-33.
Motor bracket
Taping screw
Four-way valve
Welded point
Fixing nut
Capillary assembly
—51—
Motor
Fig.8-31
Fig.8-32
Fig.8-33