Download Print this page

GE PRO AIR 107 Service Manual page 51

Split system air conditioner
Hide thumbs Also See for PRO AIR 107:

Advertisement

Operation procedures/pictures
Dismount the electric mounting board
Screw off the 3 screws fixing the electric device
installation board, and pull out the inserting
contacts for leads of compressor and fan motor,
and remove the electric device installation board
as shown in Fig.8-28.
Disassembling right sideboard
Unscrew the 5 screws that fix the right sideboard
to take out the right sideboard as shown in
Fig.8-29.
Disassembling axial flow fan
Loosen the fixing nut with a spanner, remove the
nut, spring washer and flat washer. Remove the
lower axial flow fan with force as shown in
Fig.8-30.
Screw
Fixing nut
Axial flow fan
—50—
Electric installation board
Screw
Fig.8-28
Fig.8-29
Fig.8-30

Advertisement

loading