Listing Information; Safety Label - Lopi Spirit B-Vent Gas Stove Owner's Manual

Wood gas pellet b-vent gas stove
Table of Contents

Advertisement

The safety label can be found on the rear panel. A copy is shown below.
Tested &
Listed by
Must be installed in accordance with all local codes, if any; if not, follow ANSI Z223.1 in USA, CAN B149 in Canada, and the
requirements listed in the accompanying owner's manual.
Electrical connections and grounding must be installed in accordance with local codes, if any; if not, follow ANSI/NFPA 70 in USA or
CSAC 2.21 in Canada.
Controls: Robertshaw Model 7000MVRB-5-LC
This room heater is equipped at the factory for use with natural gas, if conversion to propane (LP) fuel is desired, the
optional factory conversion kit #98900745 must be used.
Input and Orifice Specifications:
Maximum Input Rating (BTU/Hr)
Minimum Input Rating (BTU/Hr)
Front Burner Orifice (DMS)
Pressure Specifications:
Manifold Pressure HI Setting (in W.C.)
Manifold Pressure LO Setting (in W.C.)
Minimum Inlet Pressure (in W.C.)
Blower Electrical Rating: 115 Volts, 1.5 Amps, 60 Hz.
WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system of tampering with the vent
safety shutoff system can result in carbon monoxide (CO) poisoning and possible death.
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the information
in the owner's manual provided with this appliance. For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
Risk of electrical shock. Disconnect power before servicing unit.
This room heater needs fresh air for safe operation and must be installed with provisions for adequate combustion and ventilation
air. See ownerÕs installation and operating instructions.
Manufacture
Date:
Beaverton,
OR. USA
Listed Gas-Fired Vented Room Heater
Tested to ANSI Z21.11.1-1991, ANSI Z21.11.1a-1993, CAN/CGA 2.1M88, CAN/CGA 2.17M91
By OMNI Environmental Services (Report #028-S-10-5, January 1996)
L.P.
38,000
20,000
L.P.
2.7Ó
1996
Jan.
May
1997
Feb.
Jun.
1998
Mar.
Jul.
1999
Apr.
Aug.
DO NOT REMOVE THIS LABEL
L
ISTING
SPIRIT
N.G.
Minimum Clearance to Combustibles
Unit to Sidewall ....................................................10
40,000
Unit to Backwall .....................................................4
23,000
Unit to Cornerwall..................................................4
#49
#31
Alcove Minimum Width .......................................44
N.G.
Alcove Minimum Height ......................................58
Alcove Maximum Depth ......................................45
10Ó
3.5Ó
Front of Unit .........................................................36
1.0Ó
11Ó
5.5Ó
Use only with ÒBÓ vent listed chimney
FAN TYPE VENTED CIRCULATOR
Sep.
Oct.
Nov.
10850 117th Pl. N.E. Kirkland, WA 98033
Dec.
MADE IN U.S.A.
I
NFORMATION
(300GS)
P
23