Listing Label

Report 028-S-65-4
MODEL:
Liberty (520-NT)
PREVENT HOUSE FIRES - Install and use only in accordance with the manufacturer's installation and operating instructions.
Contact your local building or fire officials about restrictions and installation inspection in your area. Refer to local building codes
and manufacturer's instructions for precautions required for passing a chimney through a combustible wall or ceiling. Do not run
a chimney connector through a combustible wall or ceiling. Do not connect this unit to a chimney flue serving another appliance.
Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or other means approved by local
building or fire officials.
DANGER: Risk of electric shock. Disconnect power supply before servicing. Route power cord away from unit. Do not route power
cord over or under appliance.
DO NOT OVERFIRE - If heater or chimney connector glows, you are overfiring.
Inspect and clean chimney frequently - under certain conditions of use, creosote buildup may occur rapidly.
STANDARD RESIDENTIAL FREESTANDING INSTALLATIONS REQUIRE: 6" diameter, minimum 24 MSG black steel connector, with
listed (type HT) factory-built chimney, suitable for use with solid fuels or masonry chimney. Pedestal or legs are required.
ALCOVE INSTALLATIONS REQUIRE: One of the listed doublewall connectors shown below. Pedestal or legs are required.
Maximum alcove depth 48", minimum alcove height 84".
MOBILE HOME AND REDUCED CLEARANCE INSTALLATIONS REQUIRE: One of the listed doublewall connectors shown below. In
addition, mobile home installations require outside air - use the optional pedestal or outside air boot. Pedestal or legs are required.
• DURAVENT model DVL with DURA-PLUS chimney
• AMERI-TEC model DCC with model HS chimney
• SECURITY model DP with SECURITY model ASHT or S2100 chimney
CLEARANCES AND
FLOOR PROTECTION
A.
SIDEWALL TO UNIT
B.
BACKWALL TO UNIT
C.
CORNER TO UNIT
D.
SIDEWALL TO CONNECTOR
E.
BACKWALL TO CONNECTOR
F.
CORNERWALL TO CONNECTOR
For use with solid wood fuels only (cord wood). Operate with
feed door closed - open to feed fire only. Do not use a grate
or elevate fire - build fire directly on the hearth.
Manufactured by:
4800 Harbour Pointe Blvd. SW
www.travisproducts.com
2010
2011
IGN
© Travis Industries
Listing Label
DO NOT REMOVE THIS LABEL
LISTED SOLID FUEL BURNING APPLIANCE
SUITABLE FOR USE IN RESIDENTIAL, ALCOVE
AND MOBILE HOME INSTALLATIONS.
TESTED TO RELEVANT PORTIONS OF
UL 1482, UL 737.
FREESTANDING INSTALLATION
STANDARD RESIDENTIAL
INSTALLATION (SINGLEWALL
REQUIREMENTS:
Mukilteo, WA 98275
DATE OF MANUFACTURE
2012
Jan.
Feb.
Mar.
• METALFAB model DW connector with TG chimney
• Standard Masonry Chimney with any one of the above listed connectors.
REDUCED CLEARANCE INSTALLATIONS
CONNECTOR)
(REQUIRES DOUBLEWALL CONNECTOR)
16"
15"
9.5"
28"
18.25"
21"
MINIMUM CLEARANCES TO COMBUSTIBLES:
BACKWALL
E
D
STOVE
A
Replace glass only with LOPI supplied NEOCERAM ceramic
glass (5mm).
OPTIONAL EQUIPMENT: Rear blower (electrical rating: 115V,
60 Hz., 1.8 Amps.
Apr.
May
June
July
100-01164
SERIAL
NUMBER
MOBILE HOME, ALCOVE AND
16"
10"
7.5"
27.5"
12.75"
18.5"
NON-COMBUSTIBLE
FLOOR PROTECTION
ADJACENT WALL
B
F
45°
MIN.
C
Aug.
Sep.
Oct.
Nov.
6" MIN.
6"
STOVE
16" MIN.
Dec.
0210