Calibrating Brew Flow Rate
After initial start-up, the flow rate for the brew tank must be calibrated.
Step 1: Enter the program mode and scroll to the CALIBRATE FLOW menu and select YES.
CALIBRATE FLOW ?
NO
YES
Step 2: Menu screens will scroll displaying a message, !!!CAUTION!!! CONTAINER MUST HOLD 10 OUNCES.
Press large or small button to begin calibrating process.
!!!CAUTION!!!
Step 3: The machine will display FLOW COUNTS and a "default flow count number 657" and will start delivering hot
water out the brew outlet. The flow count number will count down to zero and the water will stop. The machine will
display a message PLEASE WAIT until the next menu in step 4 is displayed.
FLOW COUNTS
657
Step 4: Enter the amount of ounces captured in your graduated measuring container into the menu screen utilizing
the -/+ buttons and press the center button under DONE.
ENTER OZ : 10.0
(-)
DONE
Step 5: The ounces entered in step 4 are being calibrated to the flow count number precisely to the amount of water
which was delivered during the calibrate flow test. The flow count number will change and will be set as the new cali-
bration flow rate number into the control board assembly.
FLOW COUNTS/10 OZ.
643
Note: Reloading FACTORY DEFAULTS will erase the calibrated flow number and go back to the factory default
number.
Calibrating Maximum H2O Time (Hot Water)
After initial start-up, the maximum H2O time must be calibrated for the H2O tank.
Step 1: Enter the program mode and scroll to the, CALIBRATE MAXIMUM H2O TIME ?, menu and select YES.
CalibrateMaximum
NO
YES
H2O Time?
Step 2: Menu screens will scroll displaying a message !!!CAUTION!!!, "CONTAINER MUST HOLD 10 OUNCES and
PRESS HOT WATER TO START.
!!!CAUTION!!!
Step 3: Depress the Hot Water button one time and the brewer will start a timed hot water dispense. During this short
time the display will scroll the, CAUTION HOT WATER, message and stop displaying the message when the dis-
pense is finished. The screen will now say, ENTER OZ 10.0. Enter the captured ounces and depress DONE button.
ENTER OZ : 10.0
(-)
DONE
10
AutoPOD™ Training Manual
CONTAINER MUST
HOLD 10 OUNCES
FLOW COUNTS
0
(+)
CONTAINER MUST
HOLD 10 OUNCES
(+)
PRESS
BREW TO START
PLEASE WAIT
PRESS HOT
WATER TO START