Step 8: Calibrate the maximum H2O (Hot Water Tank) time
□ Access programming and go to CALIBRATE FLOW ? menu
□ Depress NO button
□ CALIBRATE MAXIMUM H2O TIME ? will be displayed. Depress the YES button
□ A series of informational screens will scroll and an instruction screen will display PRESS HOT WATER TO START
□ Place graduated measuring cup (minimum 10 ounces) under outlet
□ Depress the hot water to begin the calibration process
□ After dispense finishes, read number of ounces and enter that amount into the brewer using the +/- switches,
then press DONE to set the H2O time for a 10 ounce dispense
□ Scroll through the remaining program menus to exit programming
Step 9: Perform a coffee brew test and H2O dispense test
□ Follow "Operation" procedure in the Installation and Operating Guide for coffee brewing and hot water dispensing
□ Check levels against large and small brew ounce settings in the program menus "Brew OZ. A & Brew Oz B"
□ If ounces are off then repeat the calibration procedure in step 7
□ Check H2O dispense level for 10 ounce dispense
□ If ounces are off then repeat the calibration procedure in step 8