Brew Tank - Bunn AutoPOD Technical Training Manual

Table of Contents

Advertisement

ENTER ASSET # ?
NO
YES
SetPulseBrew A/B
NO
DONE
YES
AIR TIME A/B: 15.0
(-)
(+)
DONE
DRIP TIME A/B: 15
(-)
(+)
DONE
BREWS TO EMPTY
(-)
(+)
25
EnablEnergySavr
NO
DONE
YES
AIR PUMP POWER 4
(-)
(+)
DONE
BREW COUNT ##
NO
YES
BREW COUNT ##
RESET NEXT
CALIBRATE FLOW ?
NO
YES
CalibrateMaximum
NO
H2O Time?
YES
NUMBER OF EJECTS
SINGLE
DOUBLE
SEAL REPLACED ?
NO
YES
SERVICE TOOLS ?
NO
YES
FACTORY DEFAULTS
NO
YES
Enter Asset #
Allows you to enter in an optional 4 digit number. This can be useful for tracking the us
age of an individual machine within a group.
Set Pulse Brew (A/B)
Individually adjust on/off times. This will override BREW METER.
Air Time (A/B)
Time the brew tank is purged at the end of each brew cycle.
DRIP TIME (A/B)
Time between brew cycle and pod ejection.
Brews To Empty
Sets number of used pods need in bin to display "Empty Bin" message.
Enable Energy Saver
Choose to have the tank heaters turn off, or reduce the tank temp to 140º F, (60º C) once
the Set Idle Time has expired.
Air Pump Power (1-4)
Adjust air pressure for end of brew cycle purge. Due to pod variations, reduce as needed
if splattering occurs. Range is 1 to 4 with 1 being the weakest and 4 being the strongest.
Brew Count
Retains the total number of brew cycles completed, not resettable.
Brew Count
Retains the total number of brew cycles completed, resettable.
Calibrate Flow
Allows you to enter the actual flow rate of the sprayhead by dispensing for one minute.
The volume is then entered in ounces per minute.
Calibrate Maximum H2O Time
Allows you to enter the ounces collected in flow test and calibrates the time it takes to
deliver a 10 ounce H2O dispense.
Number of Ejects
Option of setting how many times is attempted to eject product before the next brew
cycle.
Seal Replaced
A preventive maintenance menu that is used to reset the factory setting of number of
brews back to 4500 brews for next PM countdown.
Service Tools
Allows testing of load components and switches. It should be only used by trained tech
nicians.
Factory Defaults
Resets all brew settings, calibrations back to factory presets.